 | CMDriveRemoteHttpSetHWOutTriggerMode Method |
Sets the options for the given CompreDrive HW Output trigger
Namespace: CompreDriveSDK.WCF.HttpAssembly: CompreDriveSDK (in CompreDriveSDK.dll) Version: 1.17.16
Syntaxpublic bool SetHWOutTriggerMode(
int? Triggernumber,
bool? PulseRising,
uint? PulseTime
)
Public Function SetHWOutTriggerMode (
Triggernumber As Integer?,
PulseRising As Boolean?,
PulseTime As UInteger?
) As Boolean
Parameters
- Triggernumber NullableInt32
- The trigger number to change, 1 or 2
- PulseRising NullableBoolean
- The pulse type to set for the trigger, True for a rising pulse, false for a falling pulse
- PulseTime NullableUInt32
- The duration of the pulse in Microseconds
Return Value
BooleanTrue if the options were set, false if not
Implements
ICompreDriveWCFSetHWOutTriggerMode(NullableInt32, NullableBoolean, NullableUInt32)
See Also